Generated & Distributed Power Quality Surveys

generator power survey
Specialist power quality equipment supporting a client with prime power generation power quality issues.

Power Quality Surveys

Poor or unstable power quality has a number of adverse effects on an electrical system. This can be poor power factor caused by unstable loads or electrical noise, commonly known as harmonics. Both of these can cause a number of serious issues within your systems and combined can be disastrous for power system longevity.

Poor Power Factor, Harmonics or electrical noise can cause power system component failure and more. This includes overheating, overcurrent trips, sensitive equipment damage, nuisance tripping. These can be prevented with the deployment of the correct equipment to increase the longevity and reliability of your critical power systems.

 

Pleavin Power solutions

Our team use a combination of their extensive experience and the latest technology to conduct intrusive power quality studies. This can include localised equipment investigation through to site wide power studies. Similar actions help to identify key areas of concern and areas in which significant improvements can be made. Once areas of concern are identified we can work with you to implement solutions. Some of them include installing preventative measures and advanced correctional equipment. Poor Power Factor, Harmonics & Electrical noise can all become a thing of the past.

It is important to note that in any application supported by onsite or mobile generation the load has to not only be considered for the sizing of the generator but the quality of the power that is to be consumed. For highly inductive loads or highly capacitive loads a generator over sizing calculation has to be completed to account for the adverse affects these types of load have on generated power and the negative effect It has on overall system power factor. 

In localised power generation poor power factor and harmonics can cause engines to work harder to maintain good quality output. In some cases, this can cause the generator rotor to overheat and fail when configured incorrectly. A generator operating with a poor or unstable power factor will effectively be working twice as hard as required. Therefore, increasing wear and tear, maintenance, chance of breakdown and fuel consumption.

Power Factor Explained 

Power factor is an expression of energy efficiency. It is usually expressed as a percentage—and the lower the percentage, the less efficient power usage is.

Power factor (PF) is the ratio of working power, measured in kilowatts (kW), to apparent power, measured in kilovolt amperes (kVA). Apparent power, also known as demand, is the measure of the amount of power used to run machinery and equipment during a certain period.

It is found by multiplying (kVA = V x A). The result is expressed as kVA units.

PF expresses the ratio of true power used in a circuit to the apparent power delivered to the circuit. 

A 96% power factor demonstrates more efficiency than a 75% power factor. 

PF below 95% is considered inefficient in many applications.

How To Make Sense of Power Facto

If a circuit were 100% efficient, demand would be equal to the power available. When demand is greater than the power available, a strain is placed on the utility system. Many utilities add a demand charge to the bills of large customers to offset differences between supply and demand (where supply is lower than demand). For most utilities, demand is calculated based on the average load placed within 15 to 30 minutes. If demand requirements are irregular, the utility must have more reserve capacity available than if load requirements remain constant.

Peak demand is when demand is at its highest. The challenge for utilities is delivering power to handle every customer’s peaks. Using power at the very moment of the highest demand can disrupt overall supply, unless there are enough reserves. Therefore, utilities bill for peak demand. For some larger customers, utilities might even take the largest peak and apply across the full billing period.

Utilities apply surcharges to companies with a lower power factor. The costs of lower efficiency can be steep – driving a gas-guzzling car. The lower the power factor, the less efficient the circuit and the higher the overall operating cost. The higher the operating cost, the higher the likelihood that utilities will penalize a customer for overutilization. In most circuits there is never power factor equal to one, because there is always some impedance (interference) on the power lines.

Types of power:

Beer is active power (kW)—the useful power, or the liquid beer, is the energy that is doing work. This is the part you want.

Foam is reactive power (kVAR)—the foam is wasted power or lost power. It’s the energy being produced that isn’t doing any work, such as the production of heat or vibration.

The mug is apparent power (kVA)—the mug is the demand power, or the power being delivered by the utility.

How to calculate power factor

To calculate power factor, you need a power quality analyzer or power analyzer that measures both working power (kW) and apparent power (kVA), and to calculate the ratio of kW/kVA.

The power factor formula can be expressed in other ways:

  • PF = (True power)/(Apparent power) OR
  • PF = W/VA

Where watts measure useful power while VA measures supplied power. The ratio of the two is essentially useful power to supplied power.

Power factor compares the real power being consumed to the apparent power, or demand of the load. The power available to perform work is called real power. You can avoid power factor penalties by correcting for power factor.

Poor power factor means that you’re using power inefficiently. This matters to companies because it can result in:

  • Heat damage to insulation and other circuit components
  • Reduction in the amount of available useful power
  • A required increase in conductor and equipment sizes

Finally, power factor increases the overall cost of a power distribution system because the lower power factor requires a higher current to supply the loads.

If you have any questions or would like to discuss how we can help you call our technical team on 0800 689 4803 or email [email protected]